Air conditioning machines incorporating a refrigerating unit and a valve for reversal of the cooling/heat cycle "reversible heat pumps" (excl. of a kind used for persons in motor vehicles and self-contained or "split-system" window or wall air conditioning machines) (HS code(s): 841581); Ventilation and air-conditioning systems (ICS code(s): 91.140.30)

DEAS 1213:2024, Air conditioning appliances for household and similar use — Minimum Energy Performance —Requirements, First edition; (27 page(s), in English)

This Draft East African Standard specifies the minimum energy performance and energy labelling requirements for electrical non-ducted single-split, self-contained air-cooled air conditioners, air-to-air reversible heat pumps, and portable air conditioners, with a rated cooling output of up to 16 kW placed on the market for any application.

This standard does not apply to:

·        water-cooled air conditioners,

·        water-source heat pumps,

·        multi-split air conditioners,

·        multi-split air-to-air heat pumps,

·        variable refrigerant flow systems, and

·        ducted equipment as well as non-electric energy sources.